From: Brad Smith <brad <at> cvs.openbsd.org>
Subject: CVS: cvs.openbsd.org: src
Newsgroups: gmane.os.openbsd.cvs
Date: Monday 8th September 2008 07:38:33 UTC (over 9 years ago)
CVSROOT:	/cvs
Module name:	src
Changes by:	[email protected]	2008/09/08 01:38:33

Modified files:
	sys/dev/pci    : if_txp.c 
	sys/dev/mii    : amphy.c dcphy.c inphy.c iophy.c nsphy.c rlphy.c 
	                 ukphy_subr.c 

Log message:
IEEE 802.3 Annex 28B.3 explicitly specifies the following relative
priorities of the technologies supported by 802.3 Selector Field
value.

1000BASE-T full duplex
1000BASE-T
100BASE-T2 full duplex
100BASE-TX full duplex
100BASE-T2
100BASE-T4
100BASE-TX
10BASE-T full duplex
10BAST-T

However PHY drivers did not honor the order such that 100BASE-T4 had
higher priority than 100BASE-TX full duplex. Fix a long standing bug
such that PHY drivers choose the highest common denominator ability.

This bug is exposed by a Cisco 3550 switch which inadvertently
announces 100BASE-T4 capability even though it is not capable of
100BASE-T4 operation, it is a 100BASE-TX switch.

From FreeBSD

Tested with dc(4), fxp(4), rl(4), sis(4).
 
CD: 3ms